Operating Instructions
OPERATING YOUR PELLET STOVE - CIRCUIT BOARD:
PRE-BURN INSTRUCTIONS: The burn pot liner holes must be clear and the liner installed properly
against the ignitor tube for proper operation. Check the hopper for enough pellets to start the unit.
DO NOT OPERATE THE UNIT WITH THE DOOR OR ASH PAN AJAR
MANUAL MODE:
TO START: Press the ON / OFF button. The stove will turn on. The system light will flash. The Auger
Light will flash with each pulse of the auger (the Auger Feed Rate is pre-programmed during start-up).
The Heat Level Indicator will show the Heat Level that the stove will run at after start-up.
If this is the first time the unit has been started or the unit has run out of fuel, the auger will need to
be primed. Press the Manual Auger Feed button until fuel starts to drop into the Burn Pot Liner (see
OPERATING INSTRUCTIONS; STOVE CONTROLS”).
TO OPERATE: When a fire has been established, the System Light will turn solid, the Auger Light will
continue to flash to the corresponding Heat Level setting. The Heat Level button can now be pressed to
change the desired Heat Level Output setting.
The convection blower (room air blower) will turn on. The speed of this blower is controlled by the setting
of the heat level output indicator. The convection blower can be turned OFF by depressing the convection
blower control button. When the air jacket reaches 160 °F (71 °C) the convection blower will come ON
High, cooling the unit. For the best efficiency and to prevent cycling, the convection blower should be
left on at all times.
When operating on LOW HEAT LEVEL, the feed rate can be adjusted, using the auger trim, for different
quality fuels. These settings can be used if the fire keeps going out on low (poor quality fuel). Or if the
low setting is too hot for the room (see “OPERATING INSTRUCTIONS; STOVE CONTROLS”).
THERMOSTAT / SWITCH MODE:
INITIAL START-UP: See above
OPERATION - HI / LOW MODE: When the thermostat contacts are closed the stove settings are
adjustable as per Manual Mode (see above). When the thermostat contacts open, the circuit board will
take control of the settings. The stove will drop down to a low burn until the thermostat contacts close
again. This low burn setting can be adjusted for different fuel qualities (see “OPERATING INSTRUCTIONS; STOVE
CONTROLS”). The stove will come back to the previous HEAT LEVEL setting when the thermostat contacts
close again.
OPERATION ON / OFF MODE: When the thermostat contacts close, the unit will light automatically.
Once up to temperature, the stove operates the same as in manual mode (see above). When the
thermostat contacts open, the unit automatically begins its shutdown routine. The stove will re-light
when the thermostat contacts close again.
TURNING YOUR PELLET STOVE OFF - CIRCUIT BOARD:
• MANUAL and HI / LOW mode: To turn the unit OFF, simply press the ON / OFF button. This will stop
the feed of pellets. The blowers will continue to operate and cool the stove down. When cool enough,
the stove will turn off.
• ON / OFF mode: To turn the unit OFF, turn the thermostat down or off.
DO NOT unplug unit while Combustion fan is operating.
This may lead to smoke escaping from the stove.